Confirmation of the operational reliability of building structures at the place of their installation in the building

E3S Web of Conferences, 2024

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1051/e3sconf/202447401039
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The article presents the results of full-scale static tests of two reinforced concrete columns arranged in different parts of a public building, the reliability of which was doubted due to the careless manufacture of concrete cubes before sending them for laboratory tests. Based on the doubts that arose, the construction of the object under construction was suspended with the requirement of convincing proof of the operational reliability of these load-bearing structures.