Evaluation of the quality of pile foundations by different methods

2019

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1051/matecconf/201926505013
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

At the present time, in Astana city is going on works by construction public transport system LRT (Light Railway Transport). LRT is an overhead road with two railway lines. The first stage of construction is including construction of overhead road (bridge) with 22.4 km length and 18 stations. The foundation of bridge is the bored piles with cross-section of 1.0-1.5 m and length of 8-35 m. A design bearing capacity of pile is 4500-8000 kN. Chinese drilling rigs Zoomlion was used for soil boring without casing. A polymer slurry is used to maintain the walls of boreholes in sand and gravel soils. In these conditions very important point is the integrity of concrete body of each bored piles. For checking the integrity was used two methods – the Low Strain Method and the Cross-Hole Sonic Logging. The aim of this paper is finding the advantages and disadvantages of each method which applying on testing site.