Measurement of plasma parameters at a PBI using Langmuir probe

2024

Closed access Metadata (CSL-JSON)
DOI 10.1109/icops58192.2024.10625907
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

In the Republic of Kazakhstan, as well as in leading countries, modern approaches are being implemented for studying and obtaining new unique data in the field of the controlled fusion (CF) development. One of such solutions is the creation of the Kazakhstani Materials Science Tokamak [1]. A linear plasma-beam installation (PBI) has been created at the National Research Center of the Republic of Kazakhstan to support the operation of the KTM tokamak for testing the diagnostic equipment and conducting preliminary experimental work in the field of the plasma-surface interaction [2]. There is a need to determine the parameters of the exposure and operating modes of the installation during the study of the processes of the plasma interaction with the surface. The goal of this work is to measure the plasma parameters at the PBI using the automated probe diagnostics system developed by us.