Simulation modeling and improvement of the winding drum cooling conditions

2024

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.5937/jaes0-46355
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

At the Kaz-Metiz LLP plant, there has long been a problem of insufficient drums cooling due to the scale formation, which led to the need for frequent production stops to cool them. To solve this problem, simulation modeling of cooling drums with and without scale was carried out to investigate the heat spread over the body. The results of the stationary analysis in the Ansys application showed the heat propagation across the cross-section of the drum and proved that the resulting scale, having a low thermal conductivity, significantly reduces the heat exchange from the drum wall to water, as a result, the surface of the drum is significantly overheated. Subsequently, the improved drum cooling system was implemented in "Kaz-Metiz" LLP.