It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This article presents experimental data on measuring the electron temperature and plasma concentration in the radial direction on a plasma-beam setup. The plasma parameters were determined using an automated diagnostic system based on an electric probe for two working gases, hydrogen and helium. The dependences of the electron temperature and plasma density on the change in the electron beam power and working gas pressure are determined. It is shown that with an increase in the power of the electron beam, the electron temperature in the radial direction does not change for both working media, and the maximum plasma concentration in the facility was recorded at the highest gas pressure closer to the center of the beam and amounted to 5·1016 m−3 for hydrogen and 5·1017 m−3 for helium.