Application of in-situ static load test of pile in Nur-Sultan

2023

Full text Open access: Hybrid Metadata (CSL-JSON)
DOI 10.1201/9781003299127-388
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The paper presents discussions of the bearing capacities of precast concrete piles from construction site of the Construction of multifunctional family-entertainment and tourist area in the city of Nur-Sultan, Kazakhstan. According to the design drawings construction site was planned to be installed by precast concrete piles. PCPs were composed with cross-section of 30 cm × 30 cm with the length of bottom segment 7.0m. In paper presented in-situ static vertical loading tests on C7-30 driven piles were carried out on the construction site of the Parking Zone P1, P2 of the Project ‘Construction of multifunctional family-entertainment and tourist area in the city of Nur-Sultan, from 05 to 13 February, 2021. The permissible load on the pile, taking into account the safety factor γ k = 1.2 in accordance with Standard should be taken equal to – 681 kN, 800 kN respectively.