It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

In the manuscript, as a result of comparing experimental and calculated kerrograms, it is shown that during electro-optical measurements in nitrobenzene using the Kerr effect, a strong electric field and absorption of radiation from a probing laser affect the properties of the medium under study. An estimate of such influence on the value of the Kerr constant is made. It is found that in the tip-plane system when using a ruby laser, the Kerr constant near the tip changes. The established dependence of the Kerr constant on the distance to the tip made it possible to obtain a calculated kerrogram that coincides with the experimental one. Thus, it is shown that the measuring instruments can influence the results obtained, that is, under certain conditions, the electro-optical research method is invasive. This fact should be taken into account when processing experimental kerrograms.