It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The paper analyses the existing calculation methods for steam turbine condenser. The refined methods for calculating the condenser have also been considered. The dependency of the vapor pressure in the condenser on the temperature of the cooling water and the steam flow rate into the condenser have been considered. It can be seen from the obtained dependencies that the calculation of the condenser according to the ARTI and HEI (USA) methods coincides with the passport data. It is recommended to use the ARTI and HEI (USA) techniques for equipment diagnostics, and to use the KTP and USTU-UPI techniques when studying ways to increase the efficiency of the condenser. The mathematical model of the KG2-6200 condenser has been tested at the Almaty СHPP-2.