It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The paper studies a frequency transducer of the gas concentration for detection of Helicobacter Pylori strains based on the MOSFET-bipolar transistor structure with a negative differential resistance and a highly sensitive NH3 sensor. A dynamic mathematical model of the frequency transducer of gas concentration has been developed using the state variable method which makes it possible to determinate the value of voltage or current at any point of the circuit at any particular time when the gas concentration is changed. Analytical expressions for transfer function and sensitivity equation have been obtained on the basis of the nonlinear equivalent circuit of the frequency gas concentration transducer. Sensitivity of the developed device for detecting Helicobacter Pylori strains is from 2.1 kHz/ppm to 3.4 kHz/ppm.