Simulation Modelling of Results of Measuring Surface Temperature Under Electric Voltage

2015

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1016/j.sbspro.2015.04.798
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Based on the concept of concentrated capacity and method of thermally thin layer the mathematical model of heat transfer in the system of metal frame-paraffin is created. The reduction of the mathematical model is made, the calculated formula for implementation in microcontroller of smart sensor of temperature for inaccessible surface (SS TIS) is obtained. On base of simulation modeling of measurement information with use of explicit solution of model problem it is became obvious that the absolute error of the surface temperature measurement under electric voltage can be reduced up to 1 °C.