Computing the Parameters of an Orthogonal Accelerator Based on a Wedge-Shaped Electrostatic Mirror with a 2D Field

2018

Closed access Metadata (CSL-JSON)
DOI 10.3103/s1062873818100209
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Abstract A wedge-shaped mirror with a two-dimensional field, used as an orthogonal ion accelerator and a time-of-flight mass spectrometer, is considered. A nonuniform electric field is generated in the mirror by varying the potentials on its boundary electrodes without electrostatic grids. An ion bunch extracted from the source is accelerated by a field pulse in the mirror, and its size along the direction of motion is considerably reduced. The characteristics of the proposed time-of-flight spectrometer are obtained via a Monte Carlo simulation, allowing for the thermal spread of ion velocities.