Asymptotic Time Domain Evaluation of a Single-Phase Cascade H - Bridge PWM Inverter Current Quality for Non-Equal DC Sources

2018

Closed access Metadata (CSL-JSON)
DOI 10.1109/pedg.2018.8447600
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Analytical current Total Harmonic Distortion (THD) calculation approach for a 2-level inverter introduced in late 1980s was recently generalized for a single-phase multilevel inverter with an arbitrary number of uniformly distributed voltage levels. Closed-form piecewise analytical solutions were obtained assuming relatively large switching-to-fundamental frequency ratio (asymptotic assumption) and inductance dominated loads. This paper addresses theoretical calculation of current THD for a single-phase cascade H-bridge inverter with carrier based Phase-Shifted PWM (PS-PWM) and non-equal DC sources that is relevant for distributed generation. For more than 3 H-bridges, current THD depends on non-equal DC sources switching sequence on a PWM period (carrier order). Current THD best and worst switching sequences are figured out for an arbitrary H-bridges count.