It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Transformers can be treated as a time-invariant system which can be characterized by its response to the Dirac's delta function. This impulse response is completely unique and should remain so over the system life. Therefore, it can be used as a kind of indicator to check if the internal compartments, elements or parameters have physically changed during service life. The system response is the convolution of the system impulse response with the excitation signal. This time-domain response has its equivalent response in the frequency domain. Thus, the frequency response of a time-invariant system should also remain unchanged if system parameters are unchanged. This concept can be utilized to evaluate the mechanical structure integrity as well as diagnosis of transformers and rotating machines. It is called frequency response analysis. This chapter is specifically focused on frequency response measurement and analysis of transformers.