Investigation of humidity using the muon component of cosmic rays

2017

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1088/1742-6596/936/1/012051
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Determination of humidity is one of the most important types of hydrometeorological and glaciological observations performed in agriculture, hydropower and water supply. The work is devoted to the development of physical basis of moisture determination method, based on attenuation of the flux of cosmic-ray muons. The relationship between the intensity of muons registered in the underground room of the Tien Shan mountain research station (Almaty) and relative humidity was studied. The results of studies show that the values of the normalized mutual correlation function between the rows of muon intensity and relative humidity vary from 0.3 to 0.7, depending on the coincidence scheme. The data obtained from the muon telescope located at the the Tien Shan mountain research station was used in the work.