Analysis of the influence of thermal insulation material on the thermal resistance of new facade structures with horizontal air channels

Case Studies in Construction Materials, 2023

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1016/j.cscm.2023.e02026
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The research proposes new energy-saving façade constructions with closed horizontal vents, the analysis of which was carried out in ANSYS environment by the finite element method. The result of the analysis of the thermal resistance of the developed facade structures shows that a decrease in the volume of thermal insulation material by 31.25% leads to a significant decrease in the thermal resistance of the fence for all values of the external temperature, that is, at the absolute minimum by 26.31%, at the absolute maximum temperature by 26.41%, at the average temperature of the coldest five-day security 0.92 by 26.47% and at an average temperature of the first month after the end of the heating period (April) 26.54%. A similar decrease was also observed when comparing facade structures with a heat-reflecting screen: at an absolute minimum temperature of 24.9%, at an absolute maximum temperature of 24.76%, at an average temperature of the coldest five-day security of 0.92 by 24.28% and at an average temperature of the first month after the end of the heating period (April) of 24.07%. At the same time, during the analysis, it was additionally found that with the same volume indicator of the heat-insulating material in the developed new façade constructions, the heat-reflective screen presence results in an increase in the heat resistance value by 10–19%, depending on the climatic conditions of the outdoor environment. Thus, the research results can be used in buildings’ design and construction in order to reduce heat consumption and energy saving.