Impedance Control of a Wrist Rehabilitation Robot Based on Autodidact Stiffness Learning

2022

Closed access Metadata (CSL-JSON)
DOI 10.1109/tmrb.2022.3194528
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Dynamic control of an intrinsically compliant robot is paramount to ensuring safe and synergistic assistance to the patient. This paper presents an impedance controller for the rehabilitation of stroke patients with compromised wrist motor functions. The control design employs a Koopman operator-based autodidactic system identification model to predict the anatomical stiffness of the wrist joint during its various degrees of rotational motion. The proposed impedance controller, perceiving the level of the subjects’ participation from their joint stiffness, can modify the applied force. The end-effector robot has a parallel structure that uses four biomimetic muscle actuators as parallel links between the end-effector and the base platform. The controller performance is corroborated by testing the end-effector robot with three healthy subjects.