Simulation of an interturn fault in a stator winding of a synchronous condenser

2016

Closed access Metadata (CSL-JSON)
DOI 10.3103/s1068371216040118
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

A method of simulation of interturn faults in a stator winding in steady state operating conditions of synchronous condenser is proposed. The method is based on a mathematical model with the equations of the mesh current method for phase-to-phase voltages. Expressions for active and reactive impedances of the windings are presented. The initial data for calculation of resistance and reactance of stator and rotor windings are obtained experimentally. Experiments proved that the proposed method simulates interturn faults in a stator winding with a maximum error of 5–10%.