Influence of residual gas pressure and ion implantation on the properties of nitride high-entropy alloys (TiZrAlYNb)N

2014

Closed access Metadata (CSL-JSON)
DOI 10.1109/crmico.2014.6959613
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Using methods of electronic and atomic-force microscopy, energy-dispersive analysis, laser scanning microscopy, X-ray diffraction, hardness measurements the nitrides of high-entropy alloys (TiZrAlYNb)N, obtained by cathodic-vacuum-arc-vapor-deposition, were investigated. Influence of residual gas pressure on the properties of investigated nitrides was found. In addition, comparison of structure and phase analysis of investigated coatings before and after ion implantation of the heavy negative charged Au- was conducted.