Liquidation of the emission centers on film cathode by high-voltage pulses in vacuum

2002

Closed access Metadata (CSL-JSON)
DOI 10.1109/deiv.1996.545317
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The experimental results on electrode conditioning of a vacuum gap microchannel plate-cathodoluminescent screen of an image brightness amplifier, by high-voltage pulses of nanosecond range duration, have been presented. The nanosecond conditioning liquidates emission centers on the plate output surface, increases the local screen luminescence emergence voltage up to two working voltages and decreases dark currents by 1-2.5 orders. Conditioning efficiency increases with overvoltage growth at the gap and with pulse duration decrease.