VARIATION OF SPATIALLY HETEROGENEOUS RADIATION BY COORDINATE-SENSITIVE RECEIVER

Eurasian Physical Technical Journal, 2020

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.31489/2020no1/113-118
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The developed device is intended to analyze the state of thermal insulation of underground pipelines.The proposed heat flow meter uses current heating of the sensor element in the process of temperature measurement.This will improve the accuracy of temperature measurement and maintain the reference temperature measured previously using current heating.The developed device has several identical plates, each of which can receive radiation.Formulas for determining energy parameters based on calibration of a coordinate-sensitive receiver by a spatially uniform heat flow generated by an electric current are obtained.