Spatial confinement offered by a blocker on the laser-induced breakdown spectroscopy of Ti plasma

AIP Advances, 2024

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1063/5.0201954
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Spatial confinement effects offered by a blocker on the laser-induced plasma parameters of titanium (Ti) are evaluated using the Optical Emission Spectroscopy technique. Nd:YAG (1064 nm, 10 ns) laser is used as an irradiation source. To observe the spatial confinement effects, an Al blocker at different distances of 4, 6, and 8 mm from the target is placed along the plume path. All the measurements are performed under the Ar environment at different pressures. It is observed that with increasing laser irradiance plasma parameters such as excitation temperature (Te) and electron number density (ne) increase, whereas it is vice versa true for increasing blocker distances. Without the blocker, the maximum values of Te and ne are about 7000 K and 1.4 × 1018 cm−3, respectively, at an Ar pressure of 50 Torr. A significant increase in emission intensity along with Te ≈ 9810 K and ne ≈ 2.2 × 1018 cm−3 is achieved in the presence of blocker. The results show that spatial confinement is responsible for the enhancement of Te and ne, which is attributed to the increased collisional frequency of plasma species after compression by shockwaves. The ablation pressure and shock pressure are also analytically evaluated and vary from 0.15 to 0.25 GPa and from 0.1 to 0.2 GPa, respectively, with increasing laser irradiance. With increasing blocker distances from 4 to 8 mm, the work done by reflected shockwaves to compress the plume varies from 0.02 to 0.002 mJ.