Structure, Hardness and Wear Resistance of Detonation Coating Based on Cr3C2-NiCr After Pulse-Plasma Treatment

2023

Closed access Metadata (CSL-JSON)
DOI 10.1109/nap59739.2023.10310875
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper discusses the results of a study of Cr3C2-NiCr-based detonation coatings after pulse-plasma treatment. It is determined that after pulse plasma treatment (PPT) the surface roughness value decreases by 48% and the coating friction coefficient increases by 2 times, the material microhardness of Cr3C2-NiCr coatings increases from ~12 GPa (initial) to ~16.2 GPa. It was also revealed that after pulse-plasma treatment the resistance of Cr3C2-NiCr coatings to abrasion and erosion wear increases. Pulse-plasma treatment provides formation of qualitative coatings from ceramic-metal materials of Cr3C2-NiCr system with complex heterogeneous structure-phase state where the layered structure of areas of carbide particles and matrix metal in immediate proximity from border “carbide - matrix” with allocation of disperse secondary carbides in matrix is revealed.