Forming thermal imaging system field of view with afocal lens cap

2019

Closed access Metadata (CSL-JSON)
DOI 10.1117/12.2536830
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Method of infrared lenses field of view step variation is discussed in this paper. Simple afocal lens caps based on the classic Kepler or Galilee telescopic schemes are considered. The afocal cap have to provide acceptable vignetting of the extreme rays and moderate transverse dimensions. Mersenne two-mirror system of Galilean-type was selected as the most suitable lens cap. Equations were obtained to calculate dimensional parameters of the cap in respect that vignetting coefficient should be minimal.