Computer model of the power system with inclusion of a heat pump in the process of separation

2019

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1051/e3sconf/201912401032
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The results of computer simulation of industrial processes of separation of substances with the inclusion of a heat pump are presented. Designs of heat pumps of closed type, open type, like “pipe in pipe” are considered. In the simulation software Aspen HYSYS, the adequacy of the computer model of the “rectification unit – closed type heat pump” system was checked. The results of computer simulation of the “rectification unit – open-type heat pump ’pipe in pipe’” system are presented. This system allows to increase the efficiency of the unit by 9% compared with the system of separation of substances with the inclusion of an open-type heat pump and by 14% compared with a system with the inclusion of a closed-type heat pump.