Emergency control of technological environment and electric machinery activity in coal mines

2013

Closed access Metadata (CSL-JSON)
DOI 10.1134/s1062739149020172
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The authors develop standards and design of pre-emergency, emergency and post-emergency control of mine technological environment and electric machinery activity. The electric machinery operation parameters to be controlled are energy supply of explosion-proof electric machinery, cable integrity and improper access to the machinery; the control objects are switchers and starters within an extraction district. The technological environment parameters to be controlled are gas content, including CH 4 , CO, CO 2 and O 2 , variation in mine air pressure, light, sound, temperature, acceleration or dislocation of central control unit housing. The article presents engineering solutions on subsystems of data reading, processing and storage.