Triple-Voltage Gain and Self-Balancing in a New Switched-Capacitor Seven-Level Inverter for Microgrid Integration

2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/en19041001
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

In the context of power electronic interfaces in photovoltaic (PV), fuel cell, battery, and microgrid applications, the low output voltage of the DC source necessitates a voltage-boosting inverter. This paper proposes a single-source seven-level switched-capacitor boost inverter, particularly for low-voltage applications. The proposed inverter has the capability to produce seven different output voltage levels, i.e., intermediate boosted levels, with a total gain of three times the input voltage. The inverter has the advantage of a reduced number of power switches, diodes, and a switched-capacitor unit, which allows for single-stage operation without the need for a second DC-DC converter. The operating principle of the proposed inverter is explained in detail with a complete switching state analysis, conduction path analysis, and output voltage generation. The capacitor size is calculated using a charge balance-based equation. The self-balancing capability is validated for mismatched initial voltages with a bounded steady-state ripple. To evaluate the performance of the proposed inverter in a more realistic scenario, the effects of non-ideal device characteristics are considered, and the efficiency of the inverter is estimated using a loss model. A predictive current control technique is applied to control the output current under inductive load conditions. The simulation results obtained in MATLAB/Simulink software validate the proper seven-level operation of the inverter, the self-balancing capability of the capacitors, improved output waveform quality, and current control. The proposed inverter can be extended to grid-connected applications, where conventional output filters can be applied to meet the harmonic standards.