Comparative Analysis of Model-Based and Data-Driven Control for Tendon-Driven Robotic Fingers

Mathematics, 2025

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/math13223669
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The control of tendon-driven robotic fingers presents significant challenges due to their inherent underactuation, coupled with complex non-linear dynamics arising from tendon elasticity, friction, and external disturbances. Therefore, achieving precise control of finger motion and contact interactions necessitates advanced modeling, estimation, and control strategies capable of addressing uncertainties in tendon tension, routing, and elasticity. This paper presents a comprehensive comparative study of three distinct control paradigms: feedback linearization with Proportional-Derivative (FBL-PD) control, feedback linearization with super-twisting sliding-mode algorithm (FBL-STA), and deep-deterministic reinforcement learning (DDPG-RL), for the precise trajectory tracking of a three-link tendon-driven robotic finger. Through extensive simulations, the performance of each controller is rigorously evaluated based on trajectory-tracking accuracy and robustness to varying disturbances. The results indicate that under disturbance-free conditions, the FBL-PD and FBL-STA controllers, when properly tuned, achieve precise tracking of the reference trajectory; however, they produce noticeably noisy control signals. When subjected to external disturbances, these controllers exhibit increased sensitivity, producing even noisier responses. In contrast, the DDPG-RL maintains smooth control dynamics and achieves sufficiently accurate tracking in both scenarios. This comparative analysis elucidates the strengths and weaknesses of each control strategy, offering critical insights and practical guidelines for the design and implementation of advanced control systems for dexterous tendon-driven robotic fingers.