Fast operating protection of low-voltage electric motors on reed switches sensitive for stator winding short-circuits

International Journal of Electrical Power & Energy Systems, 2025

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1016/j.ijepes.2025.111216
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

• The relationships between current phase angles and shorted turns have been identified. • Monitoring the angles between the currents allows detecting 5–10% of shorted turns. • The response time for detecting shorted turns does not exceed 5–10 ms. • A new protection device for a low-voltage electric motor (EM) is presented. This article is devoted to the development of a new device to protect asynchronous electric motors (EM) rated below 1 kV (low-voltage) from inter-turn and phase-to-phase short circuits (SC). The protection is based on monitoring the angles between the stator phase currents. Experiments were conducted with various stator winding faults: phase-to-phase SCs, inter-turn SCs, and an open-phase condition. It was experimentally proven that the principle of monitoring the angles between stator phase currents is highly sensitive for detecting inter-turn SCs, whereas traditional protections based on monitoring current magnitude or stator winding temperature are not as effective. It is shown that this principle allows detection of inter-turn SCs involving a small number of shorted turns in one phase within a very short time. A new reed-switch-based protection device for low-voltage EM was developed, which detects the aforementioned SCs faster than existing solutions while not using bulky current transformers. The use of reed switches in the device design also reduces weight and size, which for the first time enabled a mounting structure for attaching the device to a motor’s terminal box – significantly simplifying installation and expanding the device’s applicability. The developed reed-switch protection device is suitable for protecting EM stator windings and preventing emergency situations in applications requiring high-speed fault detection.