Sorption Extraction of Lithium from the Brines of the Pre-Aral Region Using Ion-Exchangers Under Static Conditions

Applied Sciences, 2025

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/app15179248
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Samples of gel-type cation exchangers of the TOKEM nomenclature were tested for lithium extraction from multicomponent natural brines. The dependencies of the extraction of Li and other impurities—Na, Ca, and Mg—on the duration of the sorption process for the tested ion-exchange resins under static conditions are presented. Metal ions can be arranged according to the degree of extraction for each ion exchanger in a row: Ca2+ < Mg2+ < Li+, Na+. Testing of ion exchangers under static conditions on technological Li-containing solutions confirms the applicability of TOKEM-140 and TOKEM-160 cation exchangers for lithium extraction. For TOKEM-140, lithium extraction over time varies from 76.2% to 73.8% and for TOKEM-160—from 73.8% to 72.4%. The ionic background of natural brines has a significant effect on the capacity of ion exchangers for lithium and forms the following series Li+ << Mg2+ < Ca2+ << Na+ relative to the obtained concentrations of metal ions in natural brine. The overlay of IR spectra of TOKEM-140 and TOKEM-160 ion exchangers before and after saturation shows slight changes in their appearance, indicating that the lithium sorption process has occurred. The values of static exchange capacity (SEC) for TOKEM-140 and TOKEM-160 cation exchangers are identical.