Performance Enhancement of Wireless Power Transfer System for Biomedical Applications

2024

Closed access Metadata (CSL-JSON)
DOI 10.1109/apmc60911.2024.10867517
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper presents a miniature defected ground structure-based wireless power transfer (WPT) system sup-porting dual-band operation. Firstly, the resonator design is accurately determined to exhibit the optimal surface current distribution. The 15-by-15 sq. mm resonator is further optimized to present the dual-band functionality. Afterward, the resonators are properly coupled at a 10 mm transfer range, resulting in WPT efficiency of 79% at 0.9 GHz and 60.5% at 1.8 GHz. Additionally, the misalignment impact on the WPT performance is evaluated and results demonstrate the robustness within a specific range of horizontal and vertical shifts.