It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Main experimental work results of obtaining plasma discharge at KTM tokamak are outlined in the paper. Results of initial prebreakdown magnetic field configuration scenario calculations by Plasmaless Tokscen numerical code and results of measuring parameters of selected scenario by diagnostic set of KTM are shown. All KTM electromagnetic system power supplies have been used during experiments on KTM tokamak. However, power supplies of central solenoid and toroidal magnetic field coils have been used only on its half project power, because of incompleteness of commissioning works.