Devising a method for predicting a blood pressure level based on electrocardiogram and photoplethysmogram signals

2022

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.15587/1729-4061.2022.265066
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Determining the level of blood pressure (BP) in a non-invasive way and without a sphygmomanometer cuff is of great relevance when conducting continuous monitoring or screening studies. In this regard, a method for predicting BP parameters based on the signals of the photoplethysmogram (PPG) and electrocardiogram (ECG) signals has been developed. It is proposed to use, as informative features, the time of pulse wave propagation (PTT) and a set of calculated pulse parameters of PPG. PTT is defined as the time intervals between the R-wave of the ECG and the corresponding characteristic points on the PPG acquired optically from the finger. As parameters of the PPG pulse, the known characteristics of this signal described in the literature are used, as well as additional informative features selected during the study. In accordance with the above, the tools of machine learning theory were used to construct a classifier model and regression models. The approach described in this paper to determine BP makes it possible to use 10-second ECG signals in any of the 12 common leads and PPG signals from any optical type of sensor. The built model of the classifier detects three levels of BP: low, normal, and high, at the accuracy metric=0.8494. The regression models predict systolic, diastolic, and mean BP parameters in accordance with the requirements of the British Hypertension Society (BHS) standard by the magnitude of the absolute error. The proposed method for assessing the level of BP involves real-time measurements and can be used in the design of measuring equipment for screening studies, as well as in continuous monitoring tasks within the framework of BHS requirements.