Design optimization of a 10 kilopixel optical band Microwave Kinetic Inductance Detector

2019

Closed access Metadata (CSL-JSON)
DOI 10.1088/1748-0221/14/12/p12011
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

In order to make improved spectral imaging measurements in the ultraviolet, visible and near infrared bands, we investigated the design of a 10 kilopixel Microwave Kinetic Inductance Detector (MKID) sensitive in these bands. We evaluate design parameters for MKIDs arrays with equally spaced resonant frequencies and high intrinsic and coupling quality factors. Resonance frequencies were chosen in the range of 2.8–4.8 GHz with an average of 2 MHz intervals. We describe the optimization of our design, including reduced cross-coupling. Through simulations, we find the average intrinsic and coupling quality factors to be on the order of 10 7 and 3 × 10 4 respectively, which are good enough for our purposes.