Development and research of a remote patient monitoring system

2024

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.53894/ijirss.v7i2.2624
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper presents an architecture design for a patient monitoring system integrated with Internet of Things (IoT) technology to detect and quantify patient stress levels. Research in remote patient prediction systems is considered one of the most important areas at present. This technology offers the potential to improve stress assessment, provide interventional treatment, and provide personalized stress management techniques. A Raspberry Pi microcontroller was used as a key controller. The unit is equipped with electroencephalography sensors, electrocardiogram sensors, glucose sensors, and electromyography sensors to record physiological signals indicative of stress, such as cardiac activity and human brain activity, a method for monitoring blood glucose levels in diabetic patients and measuring electrical activity. Muscles are collected from these four sensors and transmit information via communication channels (Wi-Fi, USB). The information obtained is transferred to a storage database, where patient data is securely stored. In the storage database, interaction between the patient and the doctor occurs via a 4G communication channel. Data is transmitted via a 4G communication channel from the storage database to the doctor’s personal computer. From the doctor’s personal computer, data is transferred to the doctor’s control panel, and from there the data is transferred to a web server, where all data is processed and the patient is monitored. In the course of research, it was found that the proposed device has 95% reliability in measuring cardiac activity and human brain activity, a method for monitoring blood glucose levels in patients with diabetes and measuring the electrical activity of muscles.