A Practical Disturbance Rejection Control Scheme for Permanent Magnet Synchronous Motors

2022

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/sym14091873
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper proposes a novel disturbance rejection control scheme for permanent magnet synchronous motor (PMSM) drives. Based on the framework of modified disturbance observer (DOB)-based control, the final topology of the proposed disturbance rejection proportional–integral (DR-PI) controller includes a pre-filter and a controller in a proportional–integral (PI) form. The proposed DR-PI control scheme is practical with a straightforward gain tuning rule. Note that the gain selection method is the main issue of not only conventional PI controllers but also advanced methods such as DOB-based controllers. In addition, by starting from the framework of modified DOB, this paper also proves that the PI controller with an pre-filter possesses a disturbance rejection ability similar to a DOB-based control method. To the best of our knowledge, this is the first time that such a simple and effective PI controller is designed for the speed control of PMSMs as well as theoretically proven to have a perfect disturbance rejection ability. This paper shows the steps of selecting the parameters of the proposed controller in terms of the parameters of a desired plant model, disturbance observer and compensator. Hence, unlike a traditional DOB case, in this approach, one can simultaneously tune the controller and observer at the same time. The appearance of the pre-filter from the modified DOB scheme solves an overshoot problem, thus the general motor operation is significantly improved, which is validated by experiments. The experimental evidence under two scenarios of load torque change and speed change prove the effectiveness of the proposed method compared to conventional PI and DOB control (DOBC) schemes. All the experiments were implemented on a 300 W PMSM of a setup manufactured by Lucas-Nuelle GmbH with a digital signal processor.