Refractive Index at Low Temperature of Tetrachloromethane and Tetrafluoroethane Cryovacuum Condensates

2020

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1021/acsomega.0c00969
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

We present low-temperature measurements of the refractive index of cryofilms of tetrachloromethane and 1,1,1,2-tetrafluoroethane at different condensation and measurement temperatures between 16 and 130 K. Using cryovacuum condensation, we have been able to obtain thin films in an amorphous state for both substances despite them being very bad glass formers. Then, we have studied the evolution of the refractive index with an increasing temperature, including by transitions to ordered or partially disordered crystalline states.