It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The main problems with existing hardware random number generators today are either low speed and/or prohibitively high cost.The physical concept and test results of sample data of the high-speed hardware true random number generator design based Hamamatsu MPPC photo sensor are shown.Main features of this concept are the high speed of the true random numbers generation (tens of Mbt/s), miniature size and estimated lower production cost.This allows the use of such a device not only in large companies and government offices but for the end-user data cryptography, in classrooms, in scientific Monte-Carlo simulations, computer games and any other place where large number of true random numbers is required.The physics of the operations principle of using a Geiger-mode avalanche photo detector is briefly discussed and the high quality of the data collected is demonstrated.