It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

A model of the dynamics of steam bubbles generating on a solid surface in porous structures and a steam-generating wall (substrate) is developed. The model is based on the filming and photography with speed camera SKS-1M. The removal of high heat fluxes (up to 2х106 W/m2) is provided by the combined action of capillary and mass forces with application of intensifiers. An analytical model is developed based on the theory of thermoelasticity. The limiting state of a poorly heat-conducting porous coating and a metal substrate has been determined. The heat fluxes were calculated from the time of spontaneous appearance of the steam nucleation (10-8) up to the time of material destruction (102 ÷ 103 s). The destruction of the coating under the action of compression forces occurs in much earlier time than the tension forces. The intervals of the heat flux within which such destruction occurs are different for the quartz coating qmax ≈ 7х107 W/m2, qmin ≈ 8х104 W/m2 and for granite coating qmax ≈ 1х107 W/m2, qmin ≈ 21х104 W/m2. Experimental units, experimental conditions, the results of the heat exchange crisis and the limiting state of the surface are presented, and critical heat fluxes are calculated. The investigated capillary-porous system, operating under the combined action of capillary and mass forces, has the advantage over pool boiling, thin-film evaporators and heat pipes.