Calculation of current total harmonic distortion for a three-phase two-level inverter with LCL-filter

2017

Closed access Metadata (CSL-JSON)
DOI 10.1109/edpe.2017.8123263
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper addresses calculation of current Total Harmonic Distortion (THD) for a three-phase two-level PWM inverter with an LCL-filter. Analytical approach introduced in late 1980s for a two-level inverter with inductance dominated load is generalized accounting for the smoothing effect of an LCL-filter. Though the obtained closed-form analytical solutions initially assume (infinitely) large ratio of switching and fundamental frequencies, they are practically accurate for the ratios of (apparent) switching and fundamental frequencies larger than 25-30. The formulas reveal a three-phase two-level PWM inverter current THD dependence on LCL-filter parameters and modulation index and can be easily modified to cover a grid-connected inverter case.