Cryogenic fracturing using liquid nitrogen on granite at elevated temperatures: a case study for enhanced geothermal systems in Kazakhstan

Scientific Reports, 2024

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1038/s41598-023-50223-z
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Abstract Cryogenic fracturing using liquid nitrogen (LN2) is a novel stimulation technology that enhances porosity, permeability, and rock-fluid contact area in subsurface formations targetted for geothermal energy extraction. In our experimental study, granite cores collected from the Zhylgyz region in South Kazakhstan were equilibrated at various elevated temperatures before treatments involving LN2 exposure time. Compression, Brazilian, and fracture toughness tests were performed on granite with starting temperatures ranging from 100 to 500 °C to quantify the impact of initial temperature on cryogenic fracturing and to compare with baseline geomechanical tests at 50 °C without LN2 exposure. The results show that LN2 cooling of hot granite induces mechanical rock failure and permeability enhancement. Moreover, the degree of thermo-fracturing augments with initial granite temperature, total freezing time, and number of freezing–thawing cycles. The peak load before failure of granite specimens, both in compression and Brazilian tests, reduces with the increased sample temperature difference and length of LN2 treatment. The fracture toughness of our semi-circular bend (SCB) LN2-treated specimens diminished with increasing temperature difference between granite and boiling point. In both experimental LN2 treatment processes, the specimens with an initial temperature of 500 °C before LN2 treatment formed many new fissures and extensions of pre-existing ones, showing that the plastic behavior is augmented. While cryo-fracturing experimental confirmation is recommended with site-specific samples in planning geothermal operations, these results in our work indicate a threshold downhole temperature, e.g., > 300 °C, for enhanced stimulation outcomes.