Energy- and Resource-Efficient Hydrodynamic Treatment of Spent Water-Based Drilling Fluids for Process-Water Reuse

2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/app16147231
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Spent water-based drilling fluids generated during the construction of technological wells impose substantial environmental, water-management, transportation, and energy burdens. Conventional practices, including storage in temporary pits, prolonged settling, and off-site disposal, do not enable process-water recovery and require repeated handling of suspensions with a high solids content. This study evaluates a pressure-driven cylindrical hydrodynamic disperser as the central component of a compact on-site treatment system. Unlike conventional mechanical mixers, the disperser contains no driven shaft within the active chamber. Particle–reagent contact is intensified through controlled jet shear, vortex-induced redistribution, and the motion of freely moving steel balls. Field-derived drilling fluids containing 30–40 wt.% solids, with densities of 1.12–1.17 g/cm3, pH values of 7.4–8.2, and median particle sizes of 15–50 μm, were treated at velocity gradients of 500–1500 s−1 for 60–180 s using Superfloc N-300 dosages of 0–100 g/t. The optimal operating conditions were G = 1300 s−1, τ = 150 s, and D = 50 g/t. Under these conditions, the separation efficiency reached 91–93%, the residual suspended-solids concentration decreased to 120–130 mg/L, process-water recovery reached 80%, sludge volume decreased by 40–60%, and specific energy consumption was approximately 0.30 kWh/m3. More intensive treatment increased the separation efficiency to 94–95% but resulted in a less favorable balance among energy consumption, reagent dosage, and resource recovery. Compared with mechanical mixing, the selected treatment system reduced flocculant consumption by 37.5%, treatment time by more than threefold, and specific energy consumption by 40%. These results support the use of modular on-site systems for process-water recirculation and reduced sludge-transport requirements at remote drilling sites.