It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper addresses calculation of current Total Harmonic Distortion (THD) for a single-phase multilevel PWM inverter with LCL-filter. Analytical approach introduced in late 1980s for a 2-level inverter with inductance dominated load is generalized for a single-phase multilevel inverter with an arbitrary number of voltage levels accounting for the smoothing effect of LCL-filter. Though the obtained closed-form analytical solutions initially assume (infinitely) large ratio of switching and fundamental frequencies, they are practically accurate for the ratios of (apparent) switching and fundamental frequencies larger than 25-30. Also suggested are simple accurate Bessel function approximations. The formulas clearly reveal a single-phase PWM inverter current THD dependence on LCL-filter parameters and modulation index for an arbitrary level count and are easily modified to cover a grid-connected case.