RESULTS OF THE FIRST EXPERIMENTAL TESTS OF THE RF PLASMA HEATING SYSTEM OF THE KTM TOKAMAK WITH AN EQUIVALENT PLASMA LOAD

2026

Full text Open access: Hybrid Metadata (CSL-JSON)
DOI 10.52676/1729-7885-2026-3-113-121
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper presents the results of the first experimental tests of the ion cyclotron radio-frequency (RF) plasma heating system of the KTM tokamak with an equivalent plasma load. Measurements of the operating parameters of the RF generator and the antenna-feeder system were carried out under conditions approximating plasma operation. The generator circuits were tuned and matched to the load, and the generation characteristics as well as the conditions for stable RF power transmission to the load were investigated. Stable operating regimes of the system and the conditions ensuring stable RF power generation were determined. The test results confirm the functionality of the main components of the RF heating system and demonstrate the possibility of further testing with plasma in the KTM tokamak.