BILATERAL VISION-LANGUAGE FRAMEWORK WITH CROSS-LATERAL ATTENTION FOR MAMMOGRAPHY

Scientific Journal of Astana IT University, 2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.37943/hlva7583
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Screening mammography is read comparatively: radiologists hold one breast against the other, and several finding categories have no meaning outside that comparison. Most automated pipelines nonetheless encode a single breast at a time. We describe Bilateral MV-CLIP, a contrastive image-text framework in which all four projections of a patient enter one forward pass and the two lateralities exchange information through a Cross-Lateral Attention block, with a learned gate and a placeholder token preserving behaviour when a projection or an entire side is unavailable. Training combines image-text and image-image objectives, graded similarity targets, and a symmetry term tying embedding geometry to recorded asymmetry status. We train on VinDr-Mammo with reports synthesised from structured annotations and evaluate by linear probing of frozen features, cross-modal retrieval and report decoding, against an independently trained single-breast model matched in backbone, optimiser, schedule and epoch budget, with checkpoints selected on a held-out validation partition. On a pre-specified composite endpoint pooling the three comparison-defined categories, fusion did not improve on that baseline: area under the curve 0.781 against 0.792, a difference of -1.1 points with a 95% confidence interval from -9.6 to +7.5. Per-category effects follow the direction the design predicts, but the partition holds 49 positive comparison-defined breasts and no difference survived correction. Retrieval is limited by weak instance-level image-text alignment rather than by report redundancy, with a pool-size-independent ranking accuracy of 0.691. On an external cohort of 11,913 patients labelled by biopsy the representations transfer at reduced discrimination, reaching 0.65 for any abnormality. We therefore report explicit bilateral comparison as plausible but, on this dataset, unconfirmed, and give confidence intervals throughout.