Development of a Method for Supervising Air and Reagent Flow Control During Copper-Sulfide Ore Flotation

Eng—Advances in Engineering, 2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/eng7100535
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The object of the study is the process of copper-sulfide ore flotation in a mechanical flotation machine. The problem of increasing the stability of the process with changing power characteristics and the limited information content of standard measuring channels was addressed. A method of supervisory control of air and flotation-reagent flow rates is proposed, combining technological parameters and visual characteristics of the froth layer. A two-channel dynamic model, a froth-state index and an algorithm for limited correction of the setpoints of local PID controllers were developed, taking into account the dead zone and amplitude and rate limits. A distinctive feature of the method is the verification of the reliability of video data and the transition to control based on technological parameters in the event of loss of the visual channel. The study is a simulation-based demonstration on a generic model of a flotation cell; no industrial data were used. The efficiency was evaluated in 50 simulation runs with stepwise, random, and combined disturbances, measurement noise, transport delays, and a temporary loss of the video signal. Compared with PID control at constant setpoints, the multimodal supervisor reduced the integral absolute error of the froth state by 66.5%, the error of the conditional (simulated) concentrate quality indicator by 48.1%, the integral squared error by 84.6%, and the standard deviations of these indicators by 49.1% and 22.3%, respectively. The reductions are relative to fixed-setpoint PID in simulation; acceptance criteria for production must be defined on industrial data. The effect is explained by the combined use of visual and technological feedback. The results were obtained by simulation; the method is designed to be integrated into a PLC–SCADA structure without replacing local circuits, and its industrial validation is the next step.