Polyacrylonitrile-Based Fibrous Sorbents for Sorption–Spectroscopic Determination of Class I–III Toxic Metal Ions: Structure, Functionalisation, and Analytical Performance

2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/polym18182218
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Fibrous polyacrylonitrile (PAN) is a versatile platform for solid-phase analytical chemistry because of its chemically transformable nitrile groups, mechanical robust-ness, and favourable fibre morphology. This review critically examines PAN-based fi-brous sorbents for sorption–spectroscopic analysis (SSA) of toxic metal ions, focusing on polyamine-modified PAN/polyethylenepolyamine/1,2-dichloroethane (PPD) and PAN/polyethylenepolyamine/acrylonitrile (PPA) matrices, iminodiacetate-containing fibrous ion-exchange (FIBAN) fibres, triethanolamine-modified PAN (PAN-T), and electrospun amidoximated PAN nanofibres (AOPAN). Relationships among polymer composition, fibre morphology, surface functionalisation, reagent immobilisation, ion transport, and optical response are evaluated with respect to sensitivity, selectivity, stability, reuse, and practical applicability. Particular attention is given to electrostat-ic/physical versus covalent immobilisation, matrix interference, and the distinction between adsorption capacity and direct solid-phase optical performance. Representa-tive systems include PPD–Arsenazo III for Pb(II), with a minimum detectable concen-tration of 0.24 μg L−1, and AMADA immobilised on a polyeth-ylene-polyamine-modified PAN matrix for Mn(II), with a reported determination limit of 0.02 μg mL−1. The review also considers sustainability, automation, nanostructured architectures, additive manufacturing, and portable optical detection. Current evi-dence indicates that no single PAN architecture is universally superior; future progress requires improved sorbent standardisation, systematic interference and leaching stud-ies, reproducible optical calibration, and validation under realistic sample conditions. Fibre diameter and porosity are also discussed as coupled determinants of diffusion, scattering, and reproducibility.