Realization and Functional Safety Assessment of the National Modular Microprocessor-Based Interlocking System KZ-MPC-MA

Applied System Innovation, 2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/asi9090186
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This study investigates the realization and verification of safety-related functions of the KZ-MPC-MA national modular microprocessor-based railway interlocking system for Kazakhstan. The work focuses on the realization stage of the IEC 61508 safety lifecycle and establishes traceability between station-specific safety requirements, interlocking algorithms, software implementation, hardware–software integration, and functional-safety assessment. The implemented interlocking logic incorporates 29 traffic safety conditions defined for the considered station configuration. A fail-safe control architecture based on central and distributed controller modules was implemented using certified safety-related industrial controllers and the SILworX development environment. A laboratory prototype was developed to verify route-setting functions, switch and signal control, and fail-safe system response under specified operational and failure conditions. Quantitative functional-safety assessment was performed using the probability of failure on demand (PFDavg) as a supplementary measure and the probability of dangerous failure per hour (PFH) as the governing criterion for continuous/high-demand operation within the defined assessment boundary and assumptions. The obtained PFH demonstrates that the investigated safety-related controller subsystem satisfies the specified SIL4 quantitative criterion. The study demonstrates the feasibility of realizing safety-related interlocking functions on the selected hardware–software platform and provides a basis for further system-level verification and validation.