A Study of the Effect of Activated Waste from Ferroalloy Production on the Performance Properties of Concrete for Reinforced Concrete Sleepers

2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/jcs10050240
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Improving the durability of reinforced concrete sleepers is essential for railway infrastructure exposed to dynamic loading, moisture, and repeated freeze–thaw action. This study proposes a material-level modification approach for heavy concrete for type 2 reinforced concrete sleepers based on the combined use of activated microsilica, a ferroalloy-production byproduct, electrolyzed mixing water, and a polycarboxylate superplasticizer. The novelty of the work lies in the preliminary electrochemical activation of microsilica in an alkaline medium and in the optimization of its joint use with KN-5 by means of second-order experimental design. The concrete was evaluated by compressive and bending strength tests, scanning electron microscopy (SEM), water-penetration testing, and freeze–thaw resistance testing. All modified mixtures outperformed the reference concrete. The highest 28-day compressive strength reached 67.0 MPa, while bending strength reached 7.26 MPa. SEM observations showed a denser and more homogeneous cement matrix with reduced capillary porosity and improved interfacial transition zones. Water resistance improved from W8 for the reference mixture to W10–W14 for the modified concretes. Most modified mixtures achieved a frost resistance grade of F500, and the composition containing 15% activated microsilica and 1.0% superplasticizer reached F550. The proposed approach is effective at the material level for producing heavy concrete with enhanced strength and durability characteristics for reinforced concrete sleeper applications.