ИССЛЕДОВАНИЕ И РАЗРАБОТКА УПРАВЛЯЕМЫХ РЕАКТОРОВ ТРАНСФОРМАТОРНОГО ТИПА С ПОДМАГНИЧИВАНИЕМ ПОСТОЯННЫМ ТОКОМ

2026

Closed access Metadata (CSL-JSON)
DOI 10.51775/2790-0886_2026_72_1_70
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

В статье представлены результаты исследований и разработки управляемых шунтирующих реакторов. Исследование проводилось путем моделирования в программном комплексе MATLAB®/Simulink® с дальнейшими расчетами параметров магнитопровода и обмоток. Приведено описание принципа работы шунтирующих реакторов. Проведен гармонический анализ токов сетевой обмотки, выявлены критерии синусоидальности потребляемого тока, в которых наблюдаются номинальные параметры режима потребления зарядной мощности линий высокого напряжения. Определено, что применение принципа полупериодного насыщения в трехстержневой конструкции реактора позволило снизить коэффициент гармоник. Разработан вариант модернизированной конструкции УШР мощностью 25 МВАр номинальным напряжением 110 кВ с трехстержневым магнитопроводом, путем определения оптимального соотношения сечений ярем и стержней с применением математических методов расчета.