Comparison of noninvasive pressure-volume loops derived from cardiac magnetic resonance and transthoracic echocardiography in normal subjects

Scientific Reports, 2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.1038/s41598-026-38095-5
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The pressure–volume (PV) loop illustrates the changing interaction between left ventricular (LV) pressure and volume throughout a cardiac cycle, and can be reconstructed noninvasively using either cardiac magnetic resonance (CMR) or transthoracic echocardiography (TTE). While reference values have been described, a direct comparison of PV loop parameters derived from CMR and TTE data within the same group of individuals has not been reported yet. In this study, we aimed to evaluate PV loop indices obtained by both techniques in a cohort of healthy volunteers. Twenty participants underwent cine-CMR and 2D-TTE examinations during the same seven-day period at the Heart Center UMC in Astana, Kazakhstan. Image datasets were post-processed with a dedicated software to derive conventional volumetric indices together with PV loop parameters: ventricular elastance (E es ), arterial elastance (E a ), ventriculo-arterial coupling (VAC), stroke work (SW), PV area (PVA), and work efficiency (WE). Statistical comparisons were performed with a significance threshold defined as p < 0.05; Bland–Altman plots assessed agreement. E es , E a , and VAC were significantly higher, while SW, PVA, and WE were significantly lower when derived from TTE compared to CMR. These findings were confirmed at the Bland-Altman analysis. Our findings suggest that values of PV loop parameters are different according to the imaging method, which may affect their translational potential. CMR and TTE are not interchangeable for PV loop evaluation, especially in the context of follow-up examinations.